The parts of a vernier caliper are the outside jaws, the inside jaws, the depth rod, the beam, the main scale, the vernier scale, the slider, the thumb wheel, and the locking screw. The jaws grip the object, and the two scales give its size.
A vernier caliper measures outside width, inside diameter, and depth. The main scale gives the whole millimeters, and the vernier scale adds the fraction between two main marks. Dial and digital calipers replace the vernier scale with a dial or a screen, and their parts are named near the end.
Parts of a Vernier Caliper Labeled Diagram

In a labeled diagram of a vernier caliper, the beam runs along the full length, with the fixed jaw on the beam. The slider moves along the beam and holds the sliding jaw and the vernier scale. The outside jaws are the large jaws, and the inside jaws are the small jaws at the top.
| Part | Where you find it |
|---|---|
| 1. Outside jaws | Large jaws that grip the outside of an object |
| 2. Inside jaws | Small jaws at the top that fit inside a hole |
| 3. Depth rod | Thin rod that slides out of the beam |
| 4. Beam | Fixed part of the caliper that holds the main scale |
| 5. Main scale | Fixed scale on the beam, marked in millimeters or inches |
| 6. Vernier scale | Sliding scale that reads the fraction between main marks |
| 7. Slider | Moving part that holds the sliding jaw and the vernier scale |
| 8. Thumb wheel | Wheel that moves the slider along the beam |
| 9. Locking screw | Screw that holds the slider at the chosen reading |

Vernier Caliper Jaws
The jaws are the measuring faces of the caliper. One jaw is fixed to the beam, and the other is part of the slider. The fixed jaw is the stationary reference for both outside and inside readings. The sliding jaw clamps around the outside of an object or expands inside a hole.
Outside Jaws
The outside jaws are the large jaws, and they measure external measurements. They give the outside diameter of a hollow cylinder, the width of a rod, or the diameter of a sphere. To use them, open the jaws, place the object between them, and close the jaws against it.
Inside Jaws
The inside jaws are the small jaws, and they are the uppermost jaws on the caliper. They measure internal diameter, such as the bore of a pipe or a hollow cylinder. The jaws are placed inside the hole and opened until they press against its walls.
Parts of a Vernier Caliper Depth Rod
The depth rod, also called the depth probe or the depth bar, measures the depth of a hole, a slot, or a recess. It is attached to the slider and slides out of the beam as the slider moves. To read a depth, slide the rod outward until it touches the bottom of the object, without excessive force.
A fitter’s trade text describes the depth bar as a probe fixed to the lower end of the sliding jaw and extending at a right angle to the measuring jaws.
Main Scale and Vernier Scale
The scales are the reading parts of the caliper. The main scale is fixed to the beam, and the vernier scale slides with the slider. Together they give the size of the object.
Most calipers measure between 150 mm and 300 mm, and the longest models reach 1,828 mm (72 in). The vernier scale on a manual caliper gives a precision from 0.1 mm to 0.02 mm. The jaws, the beam, and the scales keep the same names at every size.
Main Scale
The main scale is the primary reference scale. A metric caliper marks it every millimeter, so it reads a length to about 1 mm. An imperial caliper marks it in inches and fractions, and many calipers show both. The whole-millimeter reading is taken on the main scale at the position of the vernier zero.
Vernier Scale
The vernier scale is the sliding scale that reads the fraction between two main marks. Its divisions are slightly smaller than the main scale divisions. On a metric caliper, it gives readings to 0.1 mm or better, and its precision runs from 0.1 mm to 0.02 mm.
To read the caliper, find the vernier line that lines up exactly with a main-scale line. Add the main-scale reading to the vernier reading. On one metric caliper, a vernier mark of 6 gives 16.6 mm, and a reading of 24.0 mm means only the zero marks line up.
Parts of a Vernier Caliper Slider and Locking Screw
The slider is the moving part of the caliper. It holds the sliding jaw, the vernier scale, and the depth rod, and it moves along the beam.
The thumb wheel moves the slider and makes fine adjustments of the jaw position. It also lets one hand open and close the jaws. The locking screw secures the sliding jaw after the measurement, so the reading holds while the caliper is lifted away. Some calipers use a retainer that blocks the movable part, which helps transfer a measurement.
Least Count and Zero Error
The least count is the smallest measurement the caliper reads. It equals the value of the smallest main-scale unit divided by the number of marks on the vernier scale. A 1 mm main unit with 50 vernier marks gives a least count of 0.02 mm. A reading of 7 mm on the main scale plus 6 vernier marks gives 7 mm + (6 ร 0.02 mm) = 7.12 mm.
Zero error exists when the vernier zero does not line up with the main zero. Check it by closing the jaws and comparing the two zero marks. A positive zero error is subtracted from each reading, and a negative zero error is added.
Parts of a Dial Caliper and a Digital Caliper
Calipers differ in how they show the reading, so the parts change with the type. A vernier caliper uses a sliding scale. A dial caliper uses a pointer, and a digital caliper uses a screen.
- โ Dial caliper: The slide gives the whole inches or centimeters. A rack and pinion drives a pointer around a circular dial for the fraction, and the pointer completes one revolution per inch, per tenth of an inch, or per millimeter. The dial rotates beneath the pointer for differential measurements, and a locking lever or screw holds the slide.
- โ Digital caliper: A linear encoder replaces the rack and pinion, and a liquid-crystal display shows the reading. Buttons switch between millimeters and inches and zero the display at any point along the slide, and a hold feature keeps the reading. A 150 mm stainless steel model is rated at ยฑ 0.02 mm (0.001 in) with a resolution of 0.01 mm.
Vernier Caliper Part Names
Makers and trade texts use more than one name for several parts of a vernier caliper. The alternate names come from maker pages and trade references.
| Part | Also called |
|---|---|
| Outside jaws | External measuring jaws, large jaws |
| Inside jaws | Internal measuring jaws, small jaws |
| Depth rod | Depth probe, depth bar |
| Main scale | Primary scale, main millimeter scale |
| Slider | Moving part, movable head |
| Fixed jaw | Measuring jaw |
| Sliding jaw | Movable jaw |
| Thumb wheel | Sliding thumbwheel, thumbscrew |
| Locking screw | Lock screw |
| Vernier caliper | Vernier calliper |
FAQs
FAQs
The parts of a vernier caliper are the outside jaws, the inside jaws, the depth rod, the beam, the main scale, the vernier scale, the slider, the thumb wheel, and the locking screw. The fixed jaw and the sliding jaw make up the jaws.
Sources count eight or nine named parts, depending on the source. One diagram numbers nine: the outside jaws, the inside jaws, the depth rod, the main scale, the vernier scale, the thumb wheel, the locking screw, the slider, and the beam. A trade text numbers eight: the fixed jaw, the movable jaw, the thumb rest, the depth bar, the beam, the nibs, the locking screw, and the fine adjusting unit.
The main parts of a vernier caliper are the jaws, the beam, the main scale, the vernier scale, and the slider. The depth rod, the thumb wheel, and the locking screw complete the tool.
The depth rod measures depth. It slides out of the beam until it touches the bottom of the hole or recess.
The slider is the movable part of the caliper, and it moves along the beam. It holds the sliding jaw and the vernier scale, which is the sliding scale for the fine reading.
The parts of a dial caliper are the slide, the jaws, a rack and pinion, a pointer, and a circular dial. The dial rotates beneath the pointer, and a locking lever or screw holds the slide.
The outside jaws measure external measurements, the inside jaws measure internal diameter, and the depth rod measures depth. The scales give the reading, the thumb wheel moves the slider, and the locking screw holds it.
Related: